Silentium 100
Rw 52 dB

The complete Silentium 100 partition (profiles, gaskets, double glazing and junctions) was built into the test opening of an accredited laboratory and measured to ISO 10140-2. The single-number rating to ISO 717-1:2020 is Rw 52 dB.

Laboratory tested

Result

52Rw dB

C −1 · Ctr −4

Rw is the weighted sound reduction index: a single-number laboratory rating of airborne sound insulation. C and Ctr are the spectrum adaptation terms for mid-frequency and low-frequency dominated noise.

Test record

Result
Rw 52 dB (C −1 · Ctr −4)
Measurement standard
ISO 10140-2
Rating standard
ISO 717-1:2020
Tested specimen
6 + 6 mm laminated glass · air gap · 6 + 6 mm laminated glass
Total construction depth
100 mm
Specimen area
1.85 m²
Laboratory
GiB mbH · Arnstorf, Germany
Accreditation
DAkkS · ISO/IEC 17025 · D-PL-18520-01-00
Report number
E260327M1/1_rev00
Report date
30 March 2026
Scope of the result

What this figure covers, and what it does not.

Laboratory tested: Measured on the complete assembly at an accredited laboratory. Report reference published.

  • The figure is a laboratory value for the tested specimen described above. It is not a glass-only rating and not a calculation.
  • Other glass build-ups, heights and junction conditions are assessed per project; the tested result is not transferred to a different configuration without engineering review.
  • Performance measured on site (for example DnT,w or R′w) depends on installation quality, flanking paths through floor, ceiling and façade, and room conditions. No site measurement is claimed here.
  • Door-sets within a partition run have their own acoustic performance and are not covered by this report.
Full report

The laboratory report.

This page is a summary. The complete report, with the measured one-third-octave values and the specimen description, is issued to architects and consultants.

  • GiB test report E260327M1/1_rev00

    Acoustic test report · Silentium 100 · tested specimen · PDF · rev00 · 30 March 2026

    Full laboratory report. Issued to architects and consultants on request.

The system

Silentium 100

The benchmark for acoustic separation in commercial interiors.